IS:398 PART II
Aluminium Conductors, Galvanized steel Reinforced for the sizes upto including 520 mm Sq.
IS:7098 PART I/1988
Crosslinked Polyethylene Insulated, Thermoplastic Sheathed Cables for electric supply and control purposes, Armoured/Unarmoured , with Copper Conductor, Class 1/2, Category 01/C1(FR)/C2(FR-LSH), except for use in Mines, including Low Temperature Applications, for working Voltages up to and including 1100 V, for the following varieties:
a) Single Core for Sizes upto and including 50 Sqmm.
b) Multi-core upto and including 4 Cores Sizes upto and including 50 Sqmm.
Crosslinked Polyethylene Insulated, Thermoplastic Sheathed Cables for electric supply and control purposes, Armoured/Unarmoured , with Aluminium Conductor, Class 1/2, Category 01/C1(FR)/C2(FR-LSH), except for use in Mines, including Low Temperature Applications, for working Voltages up to and including 1100 V, for the following varieties:
a) Single Core for Sizes upto and including 185 mm.
b) multi-core upto and including 4 Cores Sizes upto and including 185 mm.
Cross Linked Poly Ethylene Insulated, Thermoplastic Sheathed Cables for Electric supply & control purposes Armoured/Unarmoured with Copper & Aluminium Conductors (Class-1&2), Category- 01, including cables for low temperature applications, for working voltage up to & Including 1100V for following varieties.:
a) Single core up to & including 400 Sqmm
b) 1.Multi core Up to & including 4 Core X 300 Sq.mm
2.Multi core Up to & including 37 Core X 2.5 Sq.mm
3.Multi core Up to & including 37 Core X 1.5 Sq.mm
IS:694/2010
| Description | Single Core Unsheathed Fixed Wiring Cables(C1.16 / Table 3) | Single Core Unsheathed Flexible Cables(C1.17 / Table 4) | 1 to 4 Core Sheathed (Circular) Fixed Wiring Cables(C1.18 / Table 5) | 1 to 4 Core Sheathed (Circular) Flexible Cables(C1.19 / Table 6) | 1 to 5 Core Sheathed (Circular) Flexible Cords(C1.19 / Table 7) | 2 Core Flat Cables(C1.22 / Table 10) | 3 Core Flat Cables(C1.22 / Table 10) |
| Conductor | A1 & Cu | Cu | A1 & Cu | Cu | Cu | A1 & Cu | A1 & Cu |
| Conductor Class | 1 & 2 | 5 | 1 & 2 | 5 | 5 | 1 & 2 & 5 | 1 & 2 & 5 |
| Size(Sqmm) | 0.5 | 0.5 | 1 | 4 | 0.5 | 0.5 | 0.5 |
| 0.75 | 0.75 | 1.5 | 6 | 0.75 | 0.75 | 0.75 | |
| 1 | 1 | 2.5 | 10 | 1 | 1 | 1 | |
| 1.5 | 1.5 | 4 | 16 | 1.5 | 1.5 | 1.5 | |
| 2.5 | 2.5 | 6 | 25 | 2.5 | 2.5 | 2.5 | |
| 4 | 4 | 10 | 35 | 4 | 4 | ||
| 6 | 6 | 16 | 50 | 6 | 6 | ||
| 10 | 10 | 25 | 70 | 10 | 10 | ||
| 16 | 16 | 35 | 95 | ||||
| 25 | 25 | 50 | 120 | ||||
| 35 | 35 | 70 | |||||
| 50 | 50 | 95 | |||||
| 70 | 70 | 120 | |||||
| 95 | 95 | ||||||
| 120 | 120 |
PVC Insulated, Unsheathed Circular cable with flexible Copper Bare Conductor Class 5, Insulation Type C, Category 01/FR/FR-LSH comma for working Voltages upto and including 1100 V for the following varieties (a) Single Core for sizes up to and including 120 sq mm
IS:1554 PART I/1988
PVC Insulated and Sheathed Heavy Duty Cables for electric supply and control purposes, Armoured/Unarmoured, with Aluminium Conductor, Class 1/2, Insulation Type C, Sheath Type ST2, Category C2(FR-LSH) /C1(FR)/01, except for use in Mines including Low Temperature Applications, for working Voltages up to and including 1100 V, for the following varieties:
(a) Single Core for sizes up to and including 185 Sqmm
(b) Multi core up to and including 4 core for sizes up to and including 185 Sqmm
PVC Insulated and Sheathed Heavy Duty Cables for electric supply and control purposes, Armoured/Unarmoured, with Copper Conductor comma Class 1/2, Insulation Type C, Sheath Type ST2 comma Category C2(FR-LSH)/C1(FR)/01, except for use in Mines including Low Temperature Applications, for working Voltages up to and including 1100 V, for the following varieties:
(a) Single Core for sizes up to and including 50 Sqmm
(b) Multi core up to and including 4 cores for sizes up to and including 50 Sqmm
PVC Insulated (HD) Cables for Electric supply & control purposes Armoured/Unarmoured with Copper & Aluminium Conductors (Class-1&2) , Insulation type -A & type –C(HR-85) and Sheath type -ST1& ST2 ,Category- 01 , including cables for low temperature applications ,for working voltage up to & Including 1100V for following varieties .:
a) Single core up to & including 630 Sqmm
b) 1.Multi cores Up to & including 4 Core upto 300 Sq.mm
2. Multi cores Up to & including 37 Core upto 2.5 Sq.mm
3.Multi cores Up to & including 61 Core upto 1.5 Sq.mIS:14255/1995
IS:14255/1995
Aerial Bunched Cables – for working voltages up to and including 1100V, XLPE insulated, including optional requirement
1. Single core –
Nominal cross section area of phase conductor- from 16 Sqmm up to & including 95 Sqmm, with street lighting conductor.
2. Three core –
Nominal cross section area of phase conductor- from 16 Sqmm up to & including 95 Sqmm, with street lighting conductor.